A thermodynamic evaluation on high pressure condenser of double effect absorption refrigeration system

dc.authoridYilmaz, Ibrahim Halil/0000-0001-7840-9162
dc.authoridSAKA, Kenan/0000-0002-2296-894X
dc.contributor.authorYilmaz, Ibrahim Halil
dc.contributor.authorSaka, Kenan
dc.contributor.authorKaynakli, Omer
dc.date.accessioned2025-01-06T17:37:31Z
dc.date.available2025-01-06T17:37:31Z
dc.date.issued2016
dc.description.abstractOne of the parameters affecting the COP of the absorption system can be considered as the thermal balance between the high pressure condenser (HPC) and the low pressure generator (LPG) since heat rejected from the HPC is utilized as an energy source by the LPG. Condensation of the water vapor in the HPC depends on the heat removal via the LPG. This circumstance is significant for making an appropriate design and a controllable system with high performance in practical applications. For this reason, a thermodynamic analysis for the HPC of a double effect series flow water/lithium bromide absorption refrigeration system was emphasized in this study. A simulation was developed to investigate the energy transfer between the HPC and LPG. The results show that the proper designation of the HPC temperature improves the COP and ECOP due its significant impact, and its value necessarily has to be higher than the outlet temperature of the LPG based on the operating scheme. Furthermore, the COP and ECOP of the absorption system can be raised in the range of 9.72-35.09% in case of 2 degrees C-temperature increment in the HPC under the described conditions to be applied. (C) 2016 Elsevier Ltd. All rights reserved.
dc.identifier.doi10.1016/j.energy.2016.07.133
dc.identifier.endpage1041
dc.identifier.issn0360-5442
dc.identifier.issn1873-6785
dc.identifier.scopus2-s2.0-84980320605
dc.identifier.scopusqualityQ1
dc.identifier.startpage1031
dc.identifier.urihttps://doi.org/10.1016/j.energy.2016.07.133
dc.identifier.urihttps://hdl.handle.net/20.500.14669/2252
dc.identifier.volume113
dc.identifier.wosWOS:000386410500090
dc.identifier.wosqualityQ1
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherPergamon-Elsevier Science Ltd
dc.relation.ispartofEnergy
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.snmzKA_20241211
dc.subjectDouble effect absorption
dc.subjectWater/lithium bromide
dc.subjectHigh pressure condenser
dc.subjectLow pressure generator
dc.subjectPerformance evaluation
dc.subjectIrreversibility
dc.titleA thermodynamic evaluation on high pressure condenser of double effect absorption refrigeration system
dc.typeArticle

Dosyalar