THERMODYNAMIC ANALYSIS OF A FLUIDIZED BED COAL COMBUSTOR STEAM PLANT IN TEXTILE INDUSTRY

dc.authoridTantekin, Atakan/0000-0002-8200-5686
dc.contributor.authorTantekin, A.
dc.contributor.authorOzdil, N. F.
dc.date.accessioned2025-01-06T17:38:02Z
dc.date.available2025-01-06T17:38:02Z
dc.date.issued2017
dc.description.abstractThe examinations of first and second laws of thermodynamics are performed on a 6.5 MW power plant, established in Adana, Turkey. The equipment for the investigated plant can be aligned as a fluidized bed coal combustor (FBCC), a heat recovery steam generator (HRSG), an economizer (ECO), fans, pumps, a cyclone and a chimney. Whole parts of equipment are investigated separately and energetic and exergetic inspections are enforced for whole parts of the plant. The maximum exergy destruction rates in the plant are obtained for the FBCC, HRSG and ECO with 95%, 3% and 1% of the whole system, respectively. Higher excess air in the system induces heat losses, especially in the FBCC component by virtue of the rising in mass flow rate of the flue gas. This situation can be considered as one of the primary reasons of irreversibility. Additionally, higher excess air induces the decrement of combustion efficiency in FBCC. Therefore, this value and adverse effects on combustion efficiency can be decreased by reducing the flow rate of air.
dc.description.sponsorshipAdana Science and Technology University Research Fund [MUHDBF.MM.2015-10]
dc.description.sponsorshipThe authors are grateful to the financial support of Adana Science and Technology University Research Fund under project no: MUHDBF.MM.2015-10.
dc.identifier.doi10.18186/journal-of-thermal-engineering.353690
dc.identifier.endpage1614
dc.identifier.issn2148-7847
dc.identifier.issue6
dc.identifier.scopus2-s2.0-85034996218
dc.identifier.scopusqualityQ3
dc.identifier.startpage1607
dc.identifier.urihttps://doi.org/10.18186/journal-of-thermal-engineering.353690
dc.identifier.urihttps://hdl.handle.net/20.500.14669/2425
dc.identifier.volume3
dc.identifier.wosWOS:000431978900009
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.language.isoen
dc.publisherYildiz Technical Univ
dc.relation.ispartofJournal of Thermal Engineering
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20241211
dc.subjectFluidized Bed
dc.subjectExergy
dc.subjectThermodynamic Analysis
dc.titleTHERMODYNAMIC ANALYSIS OF A FLUIDIZED BED COAL COMBUSTOR STEAM PLANT IN TEXTILE INDUSTRY