Energy and exergy assessment of a cogeneration system in food industry: a case study
[ X ]
Tarih
2016
Yazarlar
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Inderscience Enterprises Ltd
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
In this paper, extensive analysis of the first and second laws of the thermodynamic is performed for a 14.25 MW cogeneration system, located in Adana, Turkey. Energy demand of the consumer is around 10.5 MW while the cogeneration system produces almost 1.35 times of the consumer requirement. The analysis results show that the largest irreversibility occurs in the boiler, which is 36% of the overall system irreversibility. Moreover, the economiser and chimney have further significant irreversibilities which are 34% and 25%, respectively. This paper also investigates the relationship between the steam pressure at the boiler output and system efficiency. As the steam pressure at the boiler output increases, the exergy destruction of the boiler decreases; therefore, the efficiency of the boiler increases. In addition, there is a satisfactory combustion efficiency in this cogeneration system since there exists high molar fraction value of CO2 at the chimney output.
Açıklama
Anahtar Kelimeler
cogeneration systems, exergy, thermodynamic analysis
Kaynak
International Journal of Exergy
WoS Q Değeri
Q4
Scopus Q Değeri
Q3
Cilt
20
Sayı
2