Application of conventional and advanced exergy analyses to evaluate the performance of a ground-source heat pump (GSHP) dryer used in food drying

[ X ]

Tarih

2014

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Pergamon-Elsevier Science Ltd

Erişim Hakkı

info:eu-repo/semantics/closedAccess

Özet

Inefficiencies in an energy system can be quantitatively determined through conventional exergy analysis while sources of the irreversibilities and real improvement potential can be deducted using a relatively new method named as advanced exergy analysis. For the first time, an advanced exergy analysis is applied to a ground-source heat pump (GSHP) drying system used in food drying for evaluating its performance along with each component in this study. The results indicate that the most important system component is the condenser due to the design standpoint. The inefficiencies within the compressor could particularly be improved by structural improvements of the whole system and the remaining system components. Furthermore, the inefficiencies of other system components except for the condenser and the evaporator are mainly affected by the internal operating condition. Both the equipment design and system components' interactions of the condenser and the evaporator have a significant effect on their inefficiencies. The conventional and modified (advanced) exergy efficiency values are calculated to be 77.05% and 93.5%, respectively. (C) 2013 Elsevier Ltd. All rights reserved.

Açıklama

Anahtar Kelimeler

Drying, Heat pump, Ground-source heat pump, Exergy, Advanced exergy

Kaynak

Energy Conversion and Management

WoS Q Değeri

Q1

Scopus Q Değeri

Q1

Cilt

78

Sayı

Künye