Isolated H-bridge DC-DC converter integrated transformerless DVR for power quality improvement
dc.authorid | Tumay, Mehmet/0000-0002-6055-3761 | |
dc.contributor.author | Savrun, Murat Mustafa | |
dc.contributor.author | Koroglu, Tahsin | |
dc.contributor.author | Tan, Adnan | |
dc.contributor.author | Cuma, Mehmet Ugras | |
dc.contributor.author | Bayindir, Kamil Cagatay | |
dc.contributor.author | Tumay, Mehmet | |
dc.date.accessioned | 2025-01-06T17:44:56Z | |
dc.date.available | 2025-01-06T17:44:56Z | |
dc.date.issued | 2020 | |
dc.description.abstract | This study presents a new H-bridge DC-DC converter-based transformerless dynamic voltage restorer topology (DVR). The proposed system can compensate balanced and unbalanced voltage sag/swell that are the most common electrical power quality problems and offers advantages over conventional DVR topologies by providing the isolation with high-frequency transformer (HFT) rather than bulky injection transformers and by employing shunt converter to eliminate the requirement of an energy storage unit. The system is composed of H-bridge DC-DC converter equipped with a HFT with one primary and three secondary windings and transformerless DVR. The single-phase shift modulation method is used for each series converter independently to provide the bidirectional power flow control of DC-DC converter, whereas in-phase compensation method with a hybrid detection algorithm is used to mitigate voltage sag/swell. An LC filter is employed to attenuate the switching ripple harmonics on the output of the DVR. The performance of the proposed system is verified experimentally on a three-phase, three-wire, 380 V, 10 kVA prototype. | |
dc.description.sponsorship | Scientific and Technological Research Council of Turkey (TUBITAK) [112R028] | |
dc.description.sponsorship | The authors acknowledge the Scientific and Technological Research Council of Turkey (TUBITAK) for their full financial support (Project no. 112R028). | |
dc.identifier.doi | 10.1049/iet-pel.2019.0687 | |
dc.identifier.endpage | 926 | |
dc.identifier.issn | 1755-4535 | |
dc.identifier.issn | 1755-4543 | |
dc.identifier.issue | 5 | |
dc.identifier.scopus | 2-s2.0-85082764467 | |
dc.identifier.scopusquality | Q2 | |
dc.identifier.startpage | 920 | |
dc.identifier.uri | https://doi.org/10.1049/iet-pel.2019.0687 | |
dc.identifier.uri | https://hdl.handle.net/20.500.14669/3249 | |
dc.identifier.volume | 13 | |
dc.identifier.wos | WOS:000526671600003 | |
dc.identifier.wosquality | Q2 | |
dc.indekslendigikaynak | Web of Science | |
dc.indekslendigikaynak | Scopus | |
dc.language.iso | en | |
dc.publisher | Inst Engineering Technology-Iet | |
dc.relation.ispartof | Iet Power Electronics | |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.snmz | KA_20241211 | |
dc.subject | Dynamıc Voltage Restorer | |
dc.subject | Inverter | |
dc.subject | Compensatıon | |
dc.subject | Topologıes | |
dc.subject | Fılter | |
dc.subject | Sag | |
dc.title | Isolated H-bridge DC-DC converter integrated transformerless DVR for power quality improvement | |
dc.type | Article |