Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Pekdur, A." seçeneğine göre listele

Listeleniyor 1 - 2 / 2
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY
    (2018) Özdil, N. F.; Tantekin, A.; Pekdur, A.
    Extensive analysis of the thermodynamics first and second laws is performed on a 14.25 MW cogeneration plantin Adana, Turkey. In this study, the most important parts of the system is observed and thermodynamic performanceassessments are evaluated. The obtained outcomes indicate that major exergy destruction happens in boiler, whichis 42% of the whole system irreversibility. Moreover, the economizer and chimney have also considerableirreversibilities which are 29% and 25%, respectively. The energy efficiencies of the chimney, economizer andboiler are calculated as 61.68%, 66.03%, 79.91%, respectively. On the other hand, the exergy efficiencies ofchimney, economizer and boiler are calculated as 96.56%, 30.27% and 71.94%, respectively.
  • [ X ]
    Öğe
    PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY
    (Yildiz Technical Univ, 2018) Ozdil, N. F.; Tantekin, A.; Pekdur, A.
    Extensive analysis of the thermodynamics first and second laws is performed on a 14.25 MW cogeneration plant in Adana, Turkey. In this study, the most important parts of the system is observed and thermodynamic performance assessments are evaluated. The obtained outcomes indicate that major exergy destruction happens in boiler, which is 42% of the whole system irreversibility. Moreover, the economizer and chimney have also considerable irreversibilities which are 29% and 25%, respectively. The energy efficiencies of the chimney, economizer and boiler are calculated as 61.68%, 66.03%, 79.91%, respectively. On the other hand, the exergy efficiencies of chimney, economizer and boiler are calculated as 96.56%, 30.27% and 71.94%, respectively.

| Adana Alparslan Türkeş Bilim ve Teknoloji Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Balcalı Mahallesi, Güney Kampüs, 10. Sokak, No: 1U, Sarıçam, Adana, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2025 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim