PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY

[ X ]

Tarih

2018

Dergi Başlığı

Dergi ISSN

Cilt Başlığı

Yayıncı

Erişim Hakkı

info:eu-repo/semantics/openAccess

Özet

Extensive analysis of the thermodynamics first and second laws is performed on a 14.25 MW cogeneration plantin Adana, Turkey. In this study, the most important parts of the system is observed and thermodynamic performanceassessments are evaluated. The obtained outcomes indicate that major exergy destruction happens in boiler, whichis 42% of the whole system irreversibility. Moreover, the economizer and chimney have also considerableirreversibilities which are 29% and 25%, respectively. The energy efficiencies of the chimney, economizer andboiler are calculated as 61.68%, 66.03%, 79.91%, respectively. On the other hand, the exergy efficiencies ofchimney, economizer and boiler are calculated as 96.56%, 30.27% and 71.94%, respectively.

Açıklama

Anahtar Kelimeler

Kaynak

Journal of Thermal Engineering

WoS Q Değeri

Scopus Q Değeri

Cilt

4

Sayı

2

Künye