THE EFFECTS OF DIELECTRIC VALUES, BREAST AND TUMOR SIZE ON THE DETECTION OF BREAST TUMOR

dc.authoriduncu, nusin/0000-0003-3030-3363
dc.contributor.authorUncu, Nusin
dc.contributor.authorAydin, Emine Avsar
dc.date.accessioned2025-01-06T17:37:29Z
dc.date.available2025-01-06T17:37:29Z
dc.date.issued2019
dc.description.abstractAlthough breast cancer is the second main cause of female deaths after lung cancer, early diagnosis plays a crucial role to diminish the death rate. Many techniques have been improved to detect the cancerous cells. At different microwave frequencies, the malignant cells indicate different electrical characteristics as compared to the normal cells. According to these frequencies, the breast tissue is more permeable than other tissues such as the brain and muscle. Due to this property of the breast tissue, microwaves can be used for the detection of breast cancer. In this study, the breast prototype was modelled using the CST STUDIO SUITE electromagnetic simulation software with respect to different breast size, tumor size and dielectric values tested at a range of the 0-3.0 GHz frequency. The objective of this paper is to investigate the effects of each factor and the interactions of factors on detecting cancer cells using the factorial analysis. The results indicate that the factors such as fat and skin permittivity, tumor and breast sizes are more effective in the detection of breast tumor. Although the effect of fibro permittivity is not significant alone, there are considerable interaction effects of a large breast size and small tumor size through low-to-high values of fibro permittivity. Furthermore, the combinations of a breast radius smaller than almost 8.5 cm with a high level tumor radius and breast radius larger than 8.5 cm with a low level tumor radius are desirable for lessening the return loss value.
dc.identifier.doi10.31803/tg-20190226095826
dc.identifier.endpage203
dc.identifier.issn1846-6168
dc.identifier.issn1848-5588
dc.identifier.issue3
dc.identifier.startpage197
dc.identifier.urihttps://doi.org/10.31803/tg-20190226095826
dc.identifier.urihttps://hdl.handle.net/20.500.14669/2231
dc.identifier.volume13
dc.identifier.wosWOS:000488287600006
dc.identifier.wosqualityN/A
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherUniv North
dc.relation.ispartofTehnicki Glasnik-Technical Journal
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20241211
dc.subjectdielectric properties
dc.subjectfactorial design
dc.subjectfactor effects
dc.subjectmicrowave breast cancer detection
dc.titleTHE EFFECTS OF DIELECTRIC VALUES, BREAST AND TUMOR SIZE ON THE DETECTION OF BREAST TUMOR
dc.typeArticle

Dosyalar