Numerical investigation of heat transfer using impinging jets on triangular and square ribbed roughened walls
[ X ]
Tarih
2017
Dergi Başlığı
Dergi ISSN
Cilt Başlığı
Yayıncı
Turkish Society for Thermal Science and Technology
Erişim Hakkı
info:eu-repo/semantics/closedAccess
Özet
This paper presents a heat removal study on triangular and square ribbed surfaces under an array of impinging air jets. The investigation was carried out using nozzles with a 7x3 rectangular array of circular jets. The effect of Re number, jet-to-plate distance, and rib arrangement on heat transfer and fluid flow characteristics was examined numerically. Two arrangements have been studied. Arrangement A considers the situation when the cooling jets are directed towards the ribs, while arrangement B considers the situation when the jets are directed towards the centre line of the cavity between two ribs. Wall jets of neighboring jets have a stronger interaction with increasing Reynolds number. The lowest and highest local heat transfer for all rib geometries was obtained for H/d=8 and H/d=4-6, respectively. On triangular ribbed surfaces the stagnation point Nusselt number values for arrangement A are significantly higher than the stagnation point Nusselt numbers for arrangement B. © 2017 TIBTD Printed in Turkey.
Açıklama
Anahtar Kelimeler
CFD, Heat transfer, Impinging jet, Rib
Kaynak
Isi Bilimi Ve Teknigi Dergisi/ Journal of Thermal Science and Technology
WoS Q Değeri
Scopus Q Değeri
Q4
Cilt
37
Sayı
1