Enhancement of heat transfer using twisted tape insert in a plain tube

dc.contributor.authorGöksu, Taha Tuna
dc.contributor.authorYılmaz, Halil İbrahim
dc.date.accessioned2025-01-06T17:24:15Z
dc.date.available2025-01-06T17:24:15Z
dc.date.issued2019
dc.departmentAdana Alparslan Türkeş Bilim ve Teknoloji Üniversitesi
dc.description.abstractThe use of insert within a tube is one of the techniques enhancing the convective heat transfer coefficient at theexpense of hydraulic loss penalty. This mutual effect which is a strong function of insert geometry and flowconditions is to be analyzed in detail to improve the overall system performance. This study presents a numericalinvestigation for analyzing the thermo-hydraulic characteristics of twisted tape insert in a plain tube (with a 13-mm-diameter and 1200-mm-long) which is widely used in refrigeration applications where the compactness of theheating/cooling component is significant. The effect of twist ratio on the thermo-hydraulic performance wasconducted for the Reynolds number range of 5,025?14,871 where most of refrigeration applications are operatedin. The verification of the simulation results was compared to Dittus-Boelter empirical equation (for the plain tubecase) and good agreement was obtained. Results indicate that the variation of the twist ratio between 6?9 increasesthe friction factor and Nusselt number 197?245%, 180?220%, 163?189% and 156?179%, and 32?54%, 28?46%,28?33% and 28?33% relative to the plain tube case, respectively for the specified operating conditions. Theperformance evaluation criteria, which are measure of enhancing heat transfer against hydrodynamic forces,changed between 0.90?1.02, 0.89?1.00, 0.91?0.96 and 0.92?0.96 based on the twist ratio rise. The maximumenhancement in the performance evaluation criteria was obtained at the lowest Reynolds number and twist ratio.The performance evaluation criteria lower with increasing Reynolds number but can be increased by increasingthe twist ratio.
dc.identifier.endpage260
dc.identifier.issn2147-3129
dc.identifier.issn2147-3188
dc.identifier.issue1
dc.identifier.startpage251
dc.identifier.trdizinid379656
dc.identifier.urihttps://search.trdizin.gov.tr/tr/yayin/detay/379656
dc.identifier.urihttps://hdl.handle.net/20.500.14669/1154
dc.identifier.volume8
dc.indekslendigikaynakTR-Dizin
dc.language.isoen
dc.relation.ispartofBitlis Eren Üniversitesi Fen Bilimleri Dergisi
dc.relation.publicationcategoryMakale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.snmzKA_20241211
dc.titleEnhancement of heat transfer using twisted tape insert in a plain tube
dc.typeArticle

Dosyalar