Arşiv logosu
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
Arşiv logosu
  • Koleksiyonlar
  • Sistem İçeriği
  • Analiz
  • Talep/Soru
  • Türkçe
  • English
  • Giriş
    Yeni kullanıcı mısınız? Kayıt için tıklayın. Şifrenizi mi unuttunuz?
  1. Ana Sayfa
  2. Yazara Göre Listele

Yazar "Goksel, Bedirhan Cagri" seçeneğine göre listele

Listeleniyor 1 - 1 / 1
Sayfa Başına Sonuç
Sıralama seçenekleri
  • [ X ]
    Öğe
    Numerical and experimental analysis of a water cooled photovoltaic-thermal system using modified tubes
    (Pergamon-Elsevier Science Ltd, 2025) Variyenli, Halil Ibrahim; Yousefi, Maryam; Tuncer, Azim Dogus; Sozen, Adnan; Goksel, Bedirhan Cagri; Khanlari, Ataollah
    Photovoltaic (PV) panels often experience reduced electrical efficiency due to high operating temperatures, making effective cooling techniques critical for performance enhancement. This study investigates the overall performance of a water-cooled photovoltaic-thermal (PVT) system featuring a novel cooling tube design aimed at increasing the contact surface area between the PV module underside and cooling tubes to improve heat transfer. To achieve this, conventional circular tubes were modified into an elliptical shape with a flat surface to enhance thermal contact. Accordingly, the performance of the designed PVT system has been experimentally examined at different conditions and compared with a PV panel with the same specifications. Additionally, overall behavior of the PVT system has been numerically simulated and compared with experimental one. Experimentally obtained results exhibited successful design of the PVT system when compared to standalone PV panel. The highest electrical efficiency for the standalone PV obtained as 16.13 %. The maximum electrical efficiency for the PVT system achieved as 17.57 %. Additionally, the highest overall efficiency of the PVT was obtained as 69.38 %. Moreover, average deviation between numerically and experimentally achieved results obtained as 3.2 %. These findings indicate the potential of the proposed cooling tube design to enhance the thermal and electrical performance of PVT systems.

| Adana Alparslan Türkeş Bilim ve Teknoloji Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Balcalı Mahallesi, Güney Kampüs, 10. Sokak, No: 1U, Sarıçam, Adana, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim