DSpace Repository

Doğrusal Yükleri Besleyen Şebeke Bağlantılı PV/Akü Sisteminin Tasarımı ve Tam/Kısmi Gölgelenme Durumlarında Performans Analizi

Show simple item record

dc.contributor.author Aygul, Kemal
dc.contributor.author Demirdelen, Tugce
dc.contributor.author Tumay, Mehmet
dc.date.accessioned 2020-09-09T08:05:18Z
dc.date.available 2020-09-09T08:05:18Z
dc.date.issued 2019
dc.identifier.citation Aygül, K , Demi̇rdelen, T , Tümay, M . (2019). Doğrusal Yükleri Besleyen Şebeke Bağlantılı PV/Akü Sisteminin Tasarımı ve Tam/Kısmi Gölgelenme Durumlarında Performans Analizi . Çukurova Üniversitesi Mühendislik-Mimarlık Fakültesi Dergisi , 34 (2) , 97-112 . DOI: 10.21605/cukurovaummfd.608966 tr_TR
dc.identifier.issn 1019-1011
dc.identifier.issn 2564-7520
dc.identifier.uri http://openacccess.atu.edu.tr:8080/xmlui/handle/123456789/874
dc.identifier.uri https://doi.org/10.21605/cukurovaummfd.608966
dc.description TR Dizin indeksli yayınlar koleksiyonu. / TR Dizin indexed publications collection. tr_TR
dc.description.abstract Yenilenebilir enerji kaynaklarının kullanımı son yıllarda hızla artmaktadır. Bu durum sonucunda PV paneller ile günlük hayatta birçok uygulamada karşılaşılmaktadır. PV sistemlerin performansı çevre ve hava durumu gibi etmenlerden büyük oranda etkilenmektedir. Buna örnek olarak bulutlar, tozlanma, kar gibi nedenlerle meydana gelen gölgelenme veya kısmi gölgelenme durumlarının PV sistemlerin maksimum güç noktalarında çalışmasına neden olması gösterilebilir. Bu çalışmada bu durumun sonuçlarını incelemek üzere şebeke bağlantılı ve doğrusal yükleri besleyen bir PV/Akü sisteminin modellemesi yapılmıştır. Önerilen sistemin PSCAD ile benzetim çalışmaları yapılmış ve farklı gölgelenme senaryoları için performansı incelenmiştir. Benzetim çalışmaları sonucunda PV sistemin maksimum güç noktası izlemesi (MPPT) için kullanılan hata & gözlem (P&O) algoritmasının PV sistemin yerel maksimum noktalarında takılıp düşük verimle çalıştığı gözlenmiştir. tr_TR
dc.description.abstract The use of renewable energy sources has been increasing rapidly in recent years. As a result of this situation, PV panels are encountered in many applications in daily life. The performance of PV systems is greatly influenced by factors such as the environment and the weather. Examples include shading or partial shading conditions due to clouding, dusting and snow that cause PV systems not to operate at maximum power points. In this study, in order to analyze the results of these conditions modelling of a grid connected PV/Battery system feeding linear loads was performed. The proposed system simulated via PSCAD and the performance analysis of the system under different shading scenarios was conducted. As a result of simulation studies, it is observed that perturb and observe (P&O) algorithm used for maximum power point tracking was stuck at local maximum power points and the PV system operated at low efficiency.
dc.language.iso tr tr_TR
dc.publisher Çukurova Üniversitesi Mühendislik-Mimarlik Fakültesi Dergisi / Çukurova Üniversitesi tr_TR
dc.relation.ispartofseries 2019;Volume: 34 Issue: 2
dc.subject Mimarlık tr_TR
dc.subject Mühendislik tr_TR
dc.subject Elektrik ve Elektronik tr_TR
dc.subject Fotovoltaik tr_TR
dc.subject Akü tr_TR
dc.subject Kısmi gölgelenme tr_TR
dc.subject Maksimum güç noktası izleme tr_TR
dc.subject Photovoltaic tr_TR
dc.subject Battery tr_TR
dc.subject Partial shading tr_TR
dc.subject Maximum power point tracking tr_TR
dc.subject Personality Traits tr_TR
dc.title Doğrusal Yükleri Besleyen Şebeke Bağlantılı PV/Akü Sisteminin Tasarımı ve Tam/Kısmi Gölgelenme Durumlarında Performans Analizi tr_TR
dc.title.alternative Modeling and Performance Analysis of Grid Tied Photovoltaic Panel/Battery System Feeding Linear Loads on Complete/Partial Shading Conditions tr_TR
dc.type Article tr_TR


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse