DSpace Repository

PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY

Show simple item record

dc.contributor.author Ozdil, Naime Filiz
dc.contributor.author Tantekin, Atakan
dc.contributor.author Pekdur, Arzu
dc.date.accessioned 2019-11-22T06:24:12Z
dc.date.available 2019-11-22T06:24:12Z
dc.date.issued 2018-02
dc.identifier.citation Ozdil, N. F., Tantekin, A., & Pekdur, A. (2018). PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY. Journal of Thermal Engineering, 4(2), 1847-1854. https://doi.org/10.18186/journal-of-thermal-engineering.382412 tr_TR
dc.identifier.issn 2148-7847
dc.identifier.uri http://openaccess.adanabtu.edu.tr:8080/xmlui/handle/123456789/603
dc.identifier.uri https://doi.org/10.18186/journal-of-thermal-engineering.382412
dc.description WOS indeksli yayınlar koleksiyonu. / WOS indexed publications collection. TR Dizin indeksli yayınlar koleksiyonu. / TR Dizin indexed publications collection.
dc.description.abstract Extensive analysis of the thermodynamics first and second laws is performed on a 14.25 MW cogeneration plant in Adana, Turkey. In this study, the most important parts of the system is observed and thermodynamic performance assessments are evaluated. The obtained outcomes indicate that major exergy destruction happens in boiler, which is 42% of the whole system irreversibility. Moreover, the economizer and chimney have also considerable irreversibilities which are 29% and 25%, respectively. The energy efficiencies of the chimney, economizer and boiler are calculated as 61.68%, 66.03%, 79.91%, respectively. On the other hand, the exergy efficiencies of chimney, economizer and boiler are calculated as 96.56%, 30.27% and 71.94%, respectively. tr_TR
dc.language.iso en tr_TR
dc.publisher JOURNAL OF THERMAL ENGINEERING / YILDIZ TECHNICAL UNIV tr_TR
dc.relation.ispartofseries 2018;Volume: 4 Issue: 2 Special Issue: 7
dc.subject Cogeneration tr_TR
dc.subject Energy
dc.subject Exergy
dc.subject Thermodynamic Analysis
dc.subject Food Industry
dc.subject EXERGY ANALYSIS
dc.subject THERMODYNAMIC ANALYSIS
dc.subject RANKINE-CYCLE
dc.subject POWER-PLANTS
dc.subject NATURAL-GAS
dc.subject ENERGY
dc.subject Thermodynamics
dc.subject Fen
dc.subject Temel Bilimler
dc.subject Fizik, Uygulamalı
dc.title PERFORMANCE ASSESSMENT OF A COGENERATION SYSTEM IN FOOD INDUSTRY tr_TR
dc.type Article tr_TR


Files in this item

Files Size Format View

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Advanced Search

Browse

My Account